Beyoglu Eye Journal Digital Evaluation of the Changes in Eyelid and Ocular Surface Measurements and the Correlation of These Parameters with Visual Field Parameters After Upper Eyelid Blepharoplasty [Beyoglu Eye J]
Beyoglu Eye J. 2023; 8(2): 115-122 | DOI: 10.14744/bej.2023.24392

Digital Evaluation of the Changes in Eyelid and Ocular Surface Measurements and the Correlation of These Parameters with Visual Field Parameters After Upper Eyelid Blepharoplasty

Gülşah Gümüş1, Gamze Ozturk Karabulut2, Korhan Fazıl2, Zehra Karaagac Gunaydin3, Kubra Serefoglu Cabuk2, Damla Akman4
1Department of Ophthalmology, Dr. Ersin Arslan Training and Research Hospital, Gaziantep, Türkiye
2Department of Ophthalmology, University of Health Sciences Beyoglu Eye Training and Research Hospital, Beyoglu, Istanbul, Türkiye Sciences Beyoğlu Eye Training and Research Hospital
3Department of Ophthalmology, Dunyagoz Etiler Hospital, Istanbul, Türkiye
4Department of Public Health, Celal Bayar University, Manisa, Türkiye

OBJECTIVES: We aimed to evaluate the change in eyelid and ocular surface parameters that were measured using a digital measurement program, the change in the visual field (VF), and the correlation between ocular surface area (OSA) and VF parameters in patients who underwent upper eyelid blepharoplasty for involutional dermatochalasis.
METHODS: Patients who underwent upper eyelid blepharoplasty for involutional dermatochalasis between August 2015 and August 2019 were included in the study. The difference between preoperative and postoperative 3rd month values of manually measured margin reflex distance 1 (MRD1), digitally measured eyelid and ocular surface parameters (MRD1, MRD 2 [MRD2], upper eyelid crease height [ECH], pretarsal show height [PTH], eyebrow line-height [EBH] and OSA), and VF parameters were evaluated. The correlation between preoperative and postoperative values of manually and digi-tally measured MRD1 and also preoperative and postoperative values of OSA and VF parameters were analyzed.
RESULTS: Thirty-six eyes from 36 patients were included in this study and the mean age of patients was 57.93±7.64 years. There were statistically significant changes between preoperative and postoperative values in means of the manually measured MRD1 and the digitally measured MRD1, PTH, OSA, and ECH (p<0.001). However, the postoperative changes in the mean MRD2 and EBH were not statistically significant (p=0.664 and p=0.983). There were moderate positive cor-relations between pre- and post-operative OSA values and pre- and postoperative values of manual and digital MRD1. A statistically significant agreement was observed between the change in OSA and the change in all VF parameters (Bland–Altman analysis test).
DISCUSSION AND CONCLUSION: Digital measurements can be used to evaluate the changes in eyelid and ocular surface parameters in pa-tients who underwent upper eyelid blepharoplasty surgery. OSA provides fast results in accordance with linear measure-ments and is compatible with the change in the VF.

Keywords: Blepharoplasty, digital measurement, ocular surface area, visual field

Gülşah Gümüş, Gamze Ozturk Karabulut, Korhan Fazıl, Zehra Karaagac Gunaydin, Kubra Serefoglu Cabuk, Damla Akman. Digital Evaluation of the Changes in Eyelid and Ocular Surface Measurements and the Correlation of These Parameters with Visual Field Parameters After Upper Eyelid Blepharoplasty. Beyoglu Eye J. 2023; 8(2): 115-122